DCMburner User Manual
Every window and every setting explained · For operators, administrators and resellers
Every window and every setting explained · For operators, administrators and resellers
This manual explains DCMburner step by step, as if you have never used the program. Words in bold are buttons, tabs or fields exactly as you see them on the screen. Boxes with Tip, Note and Warning give extra help. A yellow box Not verified marks something that could not be tested while writing.
Two kinds of people use DCMburner:
| Word | Meaning |
|---|---|
| Study | One examination of one patient (for example a CT of the chest). It holds one or more series, each with images. |
| Archive | DCMburner's own storage of received studies (folder images in the data folder). Studies stay there for the time set in Setup. |
| Disc / patient disc | The CD, DVD or Blu-ray that the patient takes home. It has the images, a DICOMDIR and a viewer. |
| Publisher | The robot that loads, burns and prints discs: Epson, Primera, Zeus or Rimage. |
| Job | One order for the publisher. A burn job has a state: waiting, In-Process, Completed or Error. |
| AE title | The 'name' of a DICOM system on the network (up to 16 characters). Senders must know the AE title and port of DCMburner. |
| Profile | A set of disc settings (viewer, labels, DICOMDIR, automatic burning) that belongs to one AE title. |
| Node | Another DICOM system (PACS, modality) that DCMburner may ask for studies. |

| Button | Use |
|---|---|
| Burn Disc | Open the burn list with the selected studies and start burning. Greyed out while Filter, Q/R or Jobs is showing and nothing is selected. |
| Auto Burn | The button switches automatic burning on or off. The arrow next to it chooses which profiles burn automatically. |
| Refresh | Reloads the lists. Use it when a study just arrived. |
| Q/R | Query/Retrieve: fetch studies from another system. |
| Filter | Search the archive. Burning then works on the studies selected here. Export is disabled while Filter is showing. |
| Jobs | List of burn jobs, retrievals and imports. |
| Export | Write the ticked patients or studies to a folder. |
| Keyboard | On-screen keyboard for touch screens. |
| Setup | Settings (administrators). |
| Browser | Open the web pages in your normal browser. |
| About | Version, licence, data folder, log file, web address. |
| Close | Quit the program (asks what to do with open jobs). |

Tick Always do this to keep the answer for your Windows user; the question then no longer appears. You can change the answer at any time in Setup > Additional > Closing the window (10.7). When Windows signs out or shuts down, the question is never asked.
Browse has four areas from left to right:
Each patient and study row has two round icons at the right. The upper circle selects the row for burning; the lower disc icon shows the burn state:
| Colour | Meaning |
|---|---|
| Grey | Not burned |
| Yellow | Busy (a job is running) |
| Green | Burned (seen after completed jobs) |
| Orange | Partly burned |
| Red | Error (seen after a job that ended in Error) |
Coloured lines in front of rows come from the profile colour (Setup > Profiles).
The patients are listed with the newest received on top. When the last patient is deleted, or no patient is left, the images of the one that was shown are cleared too.
Delete from the archive (operator and administrator): point at a patient or a study and click the x at the right end of the row. After a confirmation the study (or the patient with all studies) is removed from the archive of DCMburner, with its DICOM files. Discs that were made are not affected. A study that is on a disc that is waiting or being made cannot be deleted: delete that job first (Jobs) or wait until it is finished.
In the DCMburner window the box of a study has a small solid dot before the text, between the coloured line and the text (point at it: Viewer). Click it to look at the study in the viewer of this computer (DCMviewer.exe, the same viewer as on the disc): it opens with the images of that study as they are in the archive. The viewer is taken from the copy in the settings folder of the data (C:\ProgramData\sup-c\DCMburner\settings), otherwise from the shared viewer folder (C:\Users\Public\Documents\DCMburner\viewer\sup-c). If it is in neither, or the study has no images in the archive, a message appears in the status bar. The dot is only in the DCMburner window, not in the pages in a browser on another computer: the viewer starts on the computer that holds the archive.
| Action | Result |
|---|---|
| Left-drag | Window/level (brightness and contrast) |
| Right-drag | Zoom |
| Middle button or Shift + drag | Move the image |
| Mouse wheel | Next / previous image |
| Ctrl + wheel | Zoom |
| Fit / 1:1 | Fit the image in the window / show actual pixels |
| Measure | Measure a distance |
| Play | Play the images of a series as a movie |
| Window... list | DICOM window presets (for example 1600/2800) and Auto (min-max) |

There are four ways:
| Way | How | Where described |
|---|---|---|
| Sent by a modality or PACS | The sender stores to the AE title and port of DCMburner (C-STORE). | Chapter 10 (receiver) |
| Fetched with Q/R | You ask a PACS for studies. | Chapter 5 |
| Watch folder | Copy DICOM files into C:\Users\Public\Documents\DCMburner\watchfolder. They are imported and removed from the folder. | Chapter 10 |
| Import a folder | Setup > Additional: import DICOM files from a folder (with sub-folders if you want). | Chapter 16 |

Names and descriptions are searched as 'contains' unless you type a * or ? yourself. Dates are written as dd/mm/yyyy in the boxes.
| Method | How it works | Needs |
|---|---|---|
| C-MOVE | The PACS sends the images to the DCMburner receiver. | The PACS must know DCMburner: AE title, IP address and port 4006. |
| C-GET | The PACS sends the images back over the same connection. | The PACS must support C-GET. No change in the PACS. |

Use Filter to find studies already in the archive: Patient name, Patient ID, Accession no., Study ID, Description, Modality, Study date and Received date ranges, Source AE and Burned (any, yes, no).
The list can be sorted by clicking a column title and has pages (Previous / Next). The column Burned shows if a study was already burned and Source the AE title that sent it.


After Burn the discs are first copied to the job folder (viewer, DICOM files, DICOMDIR). For a large selection that takes minutes (about 25 seconds for four DVDs of 4.4 GB on a fast disk), so a window Preparing the discs shows which disc is being made and how many files are copied. Cancel stops it: the discs that were ready are taken back and nothing is sent to the publisher. When the page is reloaded the window comes back. Only one selection is prepared at a time. Before the first file is copied DCMburner checks that the drive of the job folder has room for all discs together (and for encrypted discs for the largest disc twice); when it has not, you get a message with the needed and the free space. When a later disc fails, the discs that were ready of the same selection are taken back, so that no incomplete set is burned; the disc that failed stays in the Jobs list with its error.
Switch Auto Burn on. Studies of profiles that have Burn automatically are burned when no new images came in for the quiet period (default 20 seconds, Setup > DICOM receiver: Incoming study time-out, and AutoBurnWaitSeconds).

| State | Meaning |
|---|---|
| In-Process | The publisher is working on it. |
| Completed | The disc was written and printed. |
| Error | Something failed; the message tells what. Use Retry after you fixed it (for example blank discs or ink). |
Retrievals show the state of Q/R downloads and Imports the state of folder imports.
Every disc carries a viewer, so the patient or the doctor can look at the images without installing anything. The standard viewer is Sup-C DCMviewer (DCMviewer.exe). It is signed (publisher Cleys, Patrick), needs no installation, no administrator rights and no extra Windows components, and it runs from a CD, DVD or USB stick that cannot be written to.
DCMviewer.exe or START_VIEWER.BAT on the disc. The viewer looks for the images in its own folder and the folders above it; nobody has to choose a folder. If it finds nothing, it asks for a folder (Open folder...).| Compression on the disc | Shown by the viewer |
|---|---|
| Uncompressed, deflated, big endian | Yes |
| JPEG Baseline and Extended (8 bit), JPEG Lossless | Yes |
| JPEG-LS (lossless and near-lossless), JPEG 2000, RLE | Yes |
| JPEG Extended 12 bit, RLE with 32-bit samples, High-Throughput JPEG 2000, JPEG XL | No: the viewer says so for that image |
| MPEG-2, MPEG-4 AVC (H.264), HEVC video | Opened in the video player of Windows |
The viewer warns LOSSY COMPRESSED on images that were compressed with loss. The complete list, with every SOP class and the display rules, is in the DICOM Conformance Statement and Help of the viewer (Sup-C_DCMviewer_DICOM_Conformance_Statement_and_Help.pdf). A PDF that you put in the viewer folder is copied to every disc together with the viewer.
Export writes the ticked patients or studies exactly like a disc (viewer, DICOM files, DICOMDIR; protected like a burned disc) to a folder you choose. Use it for USB sticks or network shares. Export is disabled while Filter is showing.
Tick Anonymize in the export window to write the files without the identity of the patient (for teaching, research or a second opinion). The patient name becomes ANONYMOUS and the patient ID ANON-001, ANON-002 and so on; birth date, other IDs and names, address, institution, physicians, operators, accession number, study ID and all private attributes are removed; the UIDs of study, series and image are replaced, the same everywhere, so the studies stay together; the folder is named Anonymous 1, 2 and so on. Not changed: text that is part of the image itself (burned in) and the text inside reports (SR) and documents (PDF); look at these before you pass the files on. The dates and times of the study are kept, so that studies can be told apart. Anonymizing is not possible together with protection by birth date (one patient): set a master password or switch protection off. Anonymizing is available in the export to a folder, not (yet) for a disc: the label and the job list of a disc carry the name.
The pages you see in the DCMburner window (Browse, Filter, Q/R, burn list and Jobs) are web pages of DCMburner itself. You can open the same pages in the browser of any computer, so a colleague can look at images, search, retrieve and burn from their own desk. The screenshots in this chapter were made with Chrome. Some tasks exist only in the DCMburner window (see 9.5).
https://<name or IP address of the DCMburner computer>:8088, for example https://pacs-pc:8088. This works only when Allow other computers is on (Setup > Web access) and the Windows firewall lets port 8088 through (the installer has the task Allow DCMburner through the Windows firewall).
Each web user has one role. The role decides which pages and buttons the person sees.
| Role | Pages and actions |
|---|---|
| viewer | Browse, Search, Burn list and Jobs: look at studies and images. Cannot burn, retrieve or change anything. |
| operator | Everything a viewer does, plus Query / Retrieve, the Burn button and Retry on a failed job. |
| operator without viewer | Like operator, but images are never shown: patients and studies are listed, the viewer and thumbnails stay empty (privacy). For a secretariat that only burns. |
| admin | Everything, plus the Administration page (remote nodes, import, users). |
admin. The password was chosen at the first start of DCMburner; it cannot be looked up (see the FAQ).The top bar has the pages, your name with your role, Account and Sign out. The number on Burn list is the number of studies in your list.

Browse is the same page as in 3.2: patients, studies and series, thumbnails and the viewer, with the same mouse and key actions (3.3). Tick the circle of a patient or a study to put it on your burn list. The disc symbol shows the burn state; point at it to read it: Not burned, Burned, Partly burned, Waiting or busy burning or Error while burning. A line under the viewer reminds you of the mouse actions.

Search is the page Filter of the DCMburner window (chapter 6): fill in what you know, click Search, tick the studies and click Select for burning. The arrow at the start of a row opens the series of the study. Burned tells if a study was burned before, Source which AE title sent it.

The page is the same as Q/R (chapter 5). Pick a Node, type what you search for and click Query; Test connection checks the link. Tick studies and click Retrieve selected; the studies arrive in the archive and the progress is shown on Jobs. The column In archive tells if you have the study already: complete (green), a number such as 2 images (only part of the study is here) or no.

The list of nodes comes from the Administration page. Only nodes that are switched on (Enabled) are in the list.

The burn list holds the studies you ticked. Click ✕ to remove a study or Empty list to start over. Calculate size tells how many discs of which type are needed. Set Copies and, for more than one patient, Several patients: on one disc set or separate discs per patient. Click Burn.
The list is kept in the browser tab where you made it: it survives a refresh, but it is empty in another tab, for another user and in the DCMburner window.


Jobs has three tables and refreshes itself every few seconds:

| Part | What you can do |
|---|---|
| Remote nodes | The PACS and other systems DCMburner may query. Name, AE title, Host, Port, Retrieve (C-MOVE or C-GET) and Enabled. Save node adds or changes one; Edit and Delete are at the end of each row. The same list is in Setup > DICOM nodes. |
| Import DICOM files | Imports files from a folder on the server, that is the folder as the DCMburner computer sees it (for example D:\Disc or \\server\share\export), not a folder of the computer you are working on. Tick Include subfolders and, if you want, Delete files after import. Files that are dropped in the watch folder are imported by themselves. The progress is on Jobs. |
| Users | The web users: User, Password (Show reveals what you type) and Role. Save user adds one. Edit changes the role or sets a new password; a forgotten password cannot be read back, it is replaced by a new one. A password has at least 10 characters. The same list is in Setup > User management. |

Click Sign out when you leave a shared computer. Closing the browser tab does not affect DCMburner: the program keeps receiving and burning. The pages also work while the DCMburner window is hidden in the system tray; they stop only when DCMburner is closed with Close or Exit.
https:// and ends with :8088, and that the firewall rule exists. The FAQ lists more.Setup is for administrators. It asks for the administrator sign-in (it stays open for 10 minutes). Press Save all changes to save every tab at once. If one tab has a mistake, nothing is saved and that tab shows a warning mark. Cancel throws away the changes.
The tabs: DICOM receiver, Publisher, Media and spanning, Labels and discs, Encryption, Profiles, Additional, Web access, License, DICOM nodes, User management.

| Field | Explanation |
|---|---|
| Host name / IP address | Shown for information. Give them to the people who set up the modality. |
| AE title | Name of the receiver, up to 16 characters. Default: computer name in capitals. |
| Port | Default 4006 (104 is the DICOM standard but needs more rights on some systems). |
| Incoming study time-out | A patient counts as completely received when nothing new came in for this many seconds (default 20). Then Auto Burn starts. |
| Check the called AE title | Refuse senders that address another AE title. Leave off to accept any (the profile then follows the AE title). |
| Only accept these senders | One AE title per line; empty means everybody. |
| Allow the port in the Windows firewall... | Adds the firewall rule. |
| Import files that appear in a folder / More folders | Watch folders. The default one is always watched; add network shares if you like. |
| Remove studies after publishing | Remove studies of a completed job after the time below (hh:mm:ss, default 00:05:00). |
| Do not remove the job list | Jobs stay in the list when their studies are removed. |
| Remove studies older than N days | When DCMburner is closed, studies older than N days (default 3) are removed. 0 removes all. |
| Remove old studies when the disk is full / Free space wanted | Oldest studies go first when free space falls below the amount (default 50 GB). Studies of unfinished jobs stay. |
| Clear the archive... | Removes all studies, images and jobs. Asks for confirmation. |
| Label fields (Free 1..5) | DICOM attributes for the five free fields on labels, as tag (0010,0010) or name (PatientName). Defaults: Manufacturer, Study Description, Series Description, Body Part Examined, Source AE title. |

| Field | Explanation |
|---|---|
| Publisher | Epson Discproducer PP-xxx, Primera Bravo / Disc Publisher, All Pro Solutions (Zeus) or Rimage. Choosing fills in the usual values. |
| Publisher unit name | Epson: the unit name as TD Bridge shows it. Empty = the default unit. |
| Job folder | The folder the publisher software watches. Use Check this folder. |
| Location of CDsdk.exe (Zeus) | The PoINT software the Zeus path uses. |
| Rimage queue folder (Rimage) | The folder where DCMburner and the Rimage bridge meet: DCMburner puts jobs in Queue, the bridge writes the state in Status. The label templates go to its Labels folder. Must be the RimageQueueRoot of the bridge. For Rimage the Job folder is where DCMburner builds the disc content; the Rimage services must be able to read it. |
| Institution on the label (Rimage) | The name printed on the label for several patients (optional). |
| Prepare the Rimage folders and check the bridge (Rimage) | Makes the folders, copies the .btw templates and says whether the bridge service runs. |
| Disc type | The medium used first: CD, DVD, DVD dual layer, Blu-ray, Blu-ray dual layer. |
| File system | JOLIET, ISO9660L2 or UDF. For CD only; DVD and larger always use UDF. |
| Copies | Copies of every disc. |
| Verify after burning | Reads the disc back to check it. |
| Volume label | Name of the disc as Windows shows it (up to 32 characters). Empty = the program chooses. |
| Output stacker (Epson) | Where finished discs are put (1 to 4, see the picture). |
| Pick CD / DVD from (Primera) | Left or right bin. The two are opposite. 'Use standard settings' lets the robot choose. |
| Check discs in the bins (Primera) | Asks the robot to count its discs at start. Buttons check disc bin and clean ink cartridge are also here. |
| Burn speed | CD/DVD speed (Zeus has a maximum per medium). |
| Use the suggested values for this publisher | Fills in the standard values again. |

Usable size per disc is how many MiB DCMburner may fill; keep some room below the physical limit (CD 703, DVD 4482, DVD-DL 8145, BD 23841, BD-DL 47683 MiB).
| Option | Meaning |
|---|---|
| Spread over several discs | On: data that does not fit is split over more discs. |
| Only use the disc type from the publisher settings | On: always CD (or always DVD ...), more discs. Off: go to the next larger disc type automatically. |
| Largest disc type to switch to | Used when the option above is off. |
| Last disc may be a smaller type | For example 2 DVDs and a CD for what is left over. |

| Option | Meaning |
|---|---|
| Date layout / Date separator | How dates look on labels, for example day / month / year with /. |
| Given name before family name | Off: "Smith, John". On: "John Smith". |
| Oldest study first | Order of studies on a multi-study label. |
| Write job and label files as UTF-8 | Needed for Chinese, Cyrillic, Greek, Hebrew, Arabic and other scripts. Switch off only for old label software. |
| Leave the DICOM files off the disc | Only the viewer and other files. |
| Add .DCM to the file names | Adds the extension for software that needs it. |

With Encrypt every disc on, the disc holds only Patient.enc (AES-256, WinZip format; any current archive program opens it with the password) and the unpack program.
UnpackPatient.exe, types the password, and the files are written to the local disk and the viewer starts. Closing the window removes the files again.
What the patient does: start UnpackPatient.exe (the disc starts it by itself on Windows), type the password, click Unpack, answer Yes to "Use the temporary folder to unpack?" and wait. The files are unpacked into a temporary folder, the viewer starts, and the button changes to View Patient. When the patient closes the window, the temporary folder is removed.
Patient.enc, UnpackPatient.exe, AUTORUN.INF, message.txt and translate.lng. The archive uses WinZip AES encryption, a wrong password is refused and the master password opens it. The window texts and the question about the temporary folder follow the language chosen in DCMburner when the disc was made; this was checked for Dutch, Arabic and Lithuanian. The Yes and No buttons of that question follow the language of Windows.
A profile decides which viewer and labels go on the disc. The Default profile has the AE title of the receiver and also takes every study sent to another AE title.
| Field | Explanation |
|---|---|
| Name of the new profile / Add profile / Delete profile | Create a profile for another AE title. |
| AE title | The AE title that the sender addresses (up to 16 characters). |
| Burn automatically | Studies of this profile burn by themselves when Auto Burn is on. |
| Colour | A coloured line in front of the patients and studies of this profile. |
| Viewer folder | Everything in it is copied to the root of the disc. Default C:\Users\Public\Documents\DCMburner\viewer\sup-c. Weasis is in viewer\weasis. |
| Viewer program / Parameter | Program that opens the images. The Default profile has DCMviewer.exe filled in, the Sup-C DCMviewer that comes with DCMburner; the Parameter stays empty because that viewer finds the images on the disc itself. Empty = DCMviewer.exe or the old DCMviewer.exe, or the only program in the folder. With a program set, DCMburner writes START_VIEWER.BAT. |
| Add a DICOMDIR | The index file DICOM viewers use to open the disc. |
| Label for one patient / several patients | Label template: Epson .tdd, Primera .std, Zeus .plf, Rimage .btw in common\CDlabels. |
| Field separator (Primera/Zeus) | Separator in the label data file. |

shutdown /a cancels it). Jobs that are still open are waited for, at most 30 minutes. Put DCMburner in the Startup folder, or choose the start task of the installer, so that it starts again by itself.2026_10.csv, in C:\Users\Public\Documents\DCMburner\report. Open it with Excel.
| Item | Explanation |
|---|---|
| Port | Default 8088. |
| Allow other computers | Off: only this computer opens the pages. Takes effect when you save (the web module restarts by itself). |
| Address of the web pages / Copy | Give this address to the users. |
| Save the certificate for other computers... | Writes .cer and the install .bat. |
| Trust the certificate on this computer... | Installs the certificate here. |
| Make a certificate request for my organisation... | Creates a CSR for your certificate authority. |
| Import the answer of the certificate authority... | Imports the signed certificate. |
| Use a certificate with its key (.pfx or .crt + .key)... | Use an own certificate. |
| Use the automatic certificate again | Back to the certificate DCMburner makes by itself. |
The certificate is made for the computer name, the FQDN, localhost and all IPv4 addresses, valid 800 days, and renewed automatically. The program warns before an own certificate expires.

See the Installation Guide, chapter 6. The status shows License OK or the reason: no USB key, not activated, activation too old, file for another computer, licence ended, does not cover this version.

List of remote systems for Q/R: Name, AE title, Host, Port, Retrieve (C-MOVE or C-GET) and Enabled. Edit and Delete are at the end of each row. The program does not use DICOM TLS.

Web users: User, Password (Show reveals it) and Role (administrator, user, operator); Save user. The first administrator is admin with the password chosen at the first start. The button Open the data folder is here as well.
Studies sent to an unknown AE title use the Default profile.
TDBStatus.txt.status\SystemStatus.txt in the job folder (see the PTBurn SDK manual). DCMburner reads the file in ANSI, UTF-8 and UTF-16 (the newer Primera software writes UTF-16). When PTBurn is in the middle of writing it, the file of the robot itself (for example Disc Publisher 4200 Series.txt in the same folder) is used, and the last good status stays for a minute.ALIGN_PRINTER.PTM (Message= ALIGN_PRINTER, ClientID=Administrator, as the file of the previous version) in the job folder, once for each time the error appears. PTBurn aligns the printer by itself; this is only valid on the Disc Publisher PRO (Primera SDK 4.4). When the alignment succeeds the error goes to 0, when it fails to 31 (see the Primera manual for your model)..JDF, .INP, then .DON or .ERR). Reasons and operator requests (bin empty, ink, door) appear as a notice at the bottom.merge.dat: at most 4 studies, 30 characters per field and 700 per label.<job id>.job.json) in the Queue folder of the Rimage queue folder; the Rimage bridge (DCM2Media.Rimage.exe, a Windows service or Run-Console.cmd) picks it up, has the Rimage Software Suite make the image, record and print the disc, and writes the state in Status\<job id>.status.json.<job id>-R2, -R3, ...). A job id is used only once.<job folder>\TempCD\<job id> until the job is finished; after Completed it is removed. Delete the jobs when you close the program removes the jobs the bridge has not picked up yet.DCM2Media.Rimage.exe.config next to the bridge. A real recorder and printer need minutes; with a shorter wait the bridge stops listening before the disc is finished and the job stays In-Process. After changing them restart the bridge.RmStreaming.exe (RmDiscover_1_5_n_2.dll). It comes from RSS itself, does not affect the bridge: click OK. Do not copy files into the RSS folder.RimageMaxConcurrentJobs in DCM2Media.Rimage.exe.config, default 2; the Rimage server queues what it cannot start yet). More jobs wait in the queue (state Wait) until a place is free. This is not a fault. Only when no disc is being made and a job waits for more than a minute and a half, the bottom of the window says: The Rimage bridge does not pick up ... Is it running? After changing the number restart the bridge.DCM2Media.Rimage.exe run, hidden) when it does not. If the Windows service of the bridge is installed, the service is the one that runs it; a stopped service gives a message at the bottom of the window and DCMburner does not start a second bridge. After three starts in ten minutes it stops trying and reports it. A bridge started by DCMburner keeps running when DCMburner is closed, because it may still have discs to make. Switch the option off when you start the bridge by hand, for example with a simulator.-M1, -M2, ...) of the same order; the bridge makes them one after the other..btw template must use these merge field names): one patient PatientName, PatientID, BirthDate, StudyDate, AccessionNumber, Modality; several patients PatientCount, StudyCount, DiscNumber, DiscCount, CreatedDate, InstitutionName, JobId, PatientSummary, StudySummary. Names are written as DOE, JOHN, dates as dd/mm/yyyy, several study dates as a range, several accession numbers as Multiple.C:\ProgramData\sup-c\DCMburner\database\backup. Back up the data folder for a full copy.C:\Users\Public\Documents\DCMburner\log\yyyymmdd_dcmburner.log (see About). Send it to support when asked.See the FAQ for more. Quick list:
| Symptom | Check |
|---|---|
| Studies do not arrive | Red message at the bottom (port in use)? AE title and port at the sender (4006)? Firewall? |
| Burn is refused | Demo time over or no valid licence (status bar). |
| Job ends in Error | Message in Jobs: blank discs, ink, job folder, publisher software running? |
| Web pages not reachable from another PC | Allow other computers, firewall, certificate installed. |
| Retrieval fails with 'Cannot understand' | C-MOVE: register DCMburner in the PACS, or use C-GET. |
| Protected disc says wrong password | Use the password you gave; ASCII characters only. |