A 64-bit Windows 10 or Windows 11 computer and administrator rights.
The installer Setup_DCMburner_7.2.0_x64.exe (114 MB).
Internet access once, if Microsoft Edge WebView2 is not yet on the computer (Windows 11 has it).
The publisher software of your robot installed and working (Epson TD Bridge, Primera PTBurn or PoINT Publisher), and its job folder.
Your licence: USB key or the hardware ID of the computer (see chapter 6).
Note: DCMburner 7 installs next to an old 6.x version (it is a separate product). The old program keeps its own data in C:\ProgramData\DCMburner. Old MySQL data is not migrated.
2. Install the program
Double-click the installer. If Windows asks for administrator rights (User Account Control), choose Yes.
If Windows SmartScreen warns ("Windows protected your PC"), choose More info > Run anyway. This only happens for a file that was downloaded. The installer is code-signed: after More info the window shows the publisher (Cleys, Patrick) instead of "Unknown publisher", so you can check who made the file before you choose Run anyway. Windows warns about files it has not seen often, even when they are signed, until the file has built up a reputation.
License Agreement: read it, choose I accept the agreement and click Next. Next stays grey until you accept.
Select Destination Location: keep C:\Program Files\sup-c\DCMburner and click Next. The page says how much free space is needed (at least 329 MB). The folder gets only DCMburner.exe, the folder bin with the program and the folder uninstall; an update of an earlier build removes the many loose files that it had in the main folder.
Select Start Menu Folder: keep DCMburner and click Next.
Select Additional Tasks: choose the tasks (see the table below) and click Next.
Ready to Install: check the summary and click Install.
Installing: wait while the files are copied (about one minute).
Completing the DCMburner Setup Wizard: leave Start DCMburner ticked and click Finish.
Figure 1. Windows SmartScreen on a downloaded installer: first the warning, click More infoFigure 2. After More info: the application and the publisher of the signed installer are shown; click Run anywayFigure 3. License Agreement (after choosing I accept the agreement)Figure 4. Select Destination LocationFigure 5. Select Start Menu FolderFigure 6. Select Additional Tasks with the default choices
Task
Default
Meaning
Create an icon on the desktop
on
Adds a DCMburner icon to the desktop.
Start DCMburner when someone signs in
on
Starts the program hidden in the system tray (adds --tray). Receiving and Auto Burn then work without anybody opening the window.
Allow DCMburner through the Windows firewall
off
Adds firewall rules for the DICOM receiver and the web pages. Switch it on when other computers send studies or open the web pages.
Figure 7. Ready to Install: the summary of your choicesFigure 8. InstallingFigure 9. The last page of the wizard
Note: SmartScreen only checks files that came from the internet (they carry a "mark of the web"); a file copied from a USB stick or a network share is not checked. Tested for this guide with the installer of 8 November 2026, which is code-signed (publisher Cleys, Patrick, Certum certificate with time stamp; the signature was checked). Copied into a Windows 11 virtual machine, it started without a warning: the first window was the License Agreement. Downloaded from the internet with a browser, it showed "Windows protected your PC" (the two figures above), now with the publisher name in place of "Unknown publisher". Windows decides by reputation, so the warning goes away only after many computers have downloaded and started the same signed file; the signature does not remove it at once. The publisher is shown as it is written in the certificate: country, province, place and the name "Cleys, Patrick". The User Account Control question can be switched off by the administrator; on the test computer it is set to elevate without asking, so it is not shown here.
Leave a task out of the list to switch it off. A silent uninstallation never removes the data folder.
3. First start
Start DCMburner with the desktop icon or the Start menu.
The program asks you to choose the administrator password. The user name is admin. Use at least 10 characters. There is no ready-made password and it cannot be looked up later, so write it down in a safe place.
Type the password twice and click Create. Choose Later only for a quick look; Setup is then not protected by a password.
Setup opens by itself on the Publisher tab, with the message "Welcome. Choose your publisher and its job folder to start burning discs." at the bottom. Continue with the next chapter.
Figure 10. Setup opens on the Publisher tab after the first startFigure 11. The first start asks for the administrator passwordFigure 12. Password typed twice, ready to click Create
Warning: Keep the administrator password. If it is lost, ask your supplier for help; do not delete files in the data folder on your own.
4. Choose the publisher
In Setup > Publisher pick your robot in the Publisher list. The job folder and the usual defaults are filled in at once.
Figure 13. Setup > Publisher with the Epson defaults
Click Check this folder to see that DCMburner can reach the job folder, then Save all changes. The publisher strip at the bottom of the window shows the robot status within a few seconds.
Tip: To change the job folder later, go to Setup > Publisher again. The programs of the robot must watch the same folder.
Rimage
A Rimage publisher is not driven through a job folder of its own software, but through the Rimage bridge (DCM2Media.Rimage.exe). The bridge is installed with DCMburner, in the folder bin\rimage-bridge of the program folder, and talks to the Rimage Software Suite (RSS) that is installed on the same computer. DCMburner puts a job in the queue folder (default C:\ProgramData\sup-c\DCMburner\Rimage), the bridge makes the disc with Rimage and writes the state back.
Install the Rimage Software Suite 9.5 and set up the recorder and the printer in it. Check that Rimage works with its own tools.
Install DCMburner. On the machine of the robot, tick the task Install the Rimage bridge as a Windows service (recommended, off by default): the service also runs when nobody is signed in. Without the task, start the bridge by hand with Run-Console.cmd in bin\rimage-bridge, and try it first this way.
Open Setup > Publisher, choose Rimage. Start the Rimage bridge with DCMburner is on by default: DCMburner then starts the bridge (the Rimage bridge program field, empty = the bridge that comes with DCMburner) when it is not running. With the Windows service installed, the service does it and DCMburner does not start a second bridge. Switch the option off when you start a bridge by hand (a simulator). Check the Job folder (where DCMburner builds the disc content) and the Rimage queue folder. The queue folder must be the one the bridge uses (RimageQueueRoot in DCM2Media.Rimage.exe.config; the installer sets both to the same folder).
Click Prepare the Rimage folders and check the bridge. DCMburner makes the folders, copies the label templates and says whether the bridge service runs.
Choose the label templates in Setup > Profiles (the Default profile suggests Rimage_Single_Patient.btw and Rimage_Multi_Patient.btw) and click Save all changes.
Warning: The Rimage services must be able to read the job folder and the queue folder. Both hold patient data. Only one bridge may run for the same client id (RimageClientId in the configuration); never run two at once.
Not verified: The Rimage publisher was tested with the job files, the status files and the label fields (the job files were read by the real bridge reader), but not with the Rimage Software Suite, a recorder or a printer. Burning and printing on real hardware, and the installation of the bridge service, are for the first test at a Rimage site.
5. Set the receiver and the firewall
Setup > DICOM receiver: the AE title defaults to the computer name in capitals and the port to 4006. Give the AE title and port to the people who configure the modalities and PACS.
Press Allow the port in the Windows firewall... if you did not select the firewall task during installation.
Setup > Web access: switch Allow other computers on only when others must open the web pages; also allow the port (default 8088).
Figure 14. Setup > DICOM receiver
6. Licence
Without a licence DCMburner is a demonstration: one hour per program start, every patient name on a disc is replaced by DCMburner^Demo, and burning is refused afterwards. A red banner shows this.
Open Setup > License. There are two ways, which can also be combined:
Way 1: USB key
Plug in the USB key (Rockey4ND). The page says "USB key found, serial number ...".
Click Download the activation list (needs internet; it fetches USPK.lic from sup-c.com), or click Request an activation code by e-mail... and send the mail to info@sup-c.com.
If you received a file USPK.lic yourself, use Load the activation list (USPK.lic)....
Click Check the licence again.
Way 2: licence file for this computer
Copy the Hardware ID (button Copy) and send it to your supplier, or use Request a licence file by e-mail....
When you get DCMburner.lic, click Import the licence file....
Click Check the licence again.
Figure 15. Setup > License after activation with the USB key (key number and hardware ID hidden)
The page then shows Valid license in green, with the key number, its registration date and "Licensed by: way 1, the USB key with the activation list". The status bar shows License OK in green. About shows the licensee, end date and key number. Licence files are stored in C:\ProgramData\sup-c\DCMburner\license and the key is checked again every 30 seconds.
Figure 16. Setup > License with a licence file for this computer (no USB key; hardware ID hidden)
Kinds of licence
Kind
How
Setup shows
USB key + activation list
Key plugged in and USPK.lic loaded
Valid license; Licensed by: way 1
Licence file with end date (for example one year)
DCMburner.lic for this computer
Valid licence (file); Licence file for <computer>, bound to this computer. Valid until <date>.
Licence file without end date (lifetime)
DCMburner.lic for this computer
Valid licence (file); Licence file for <computer>, bound to this computer (no end date shown).
What you see when something is wrong
Figure 17. A licence file made for another computer (the computer codes are hidden)Figure 18. The banner and status bar in that case: demonstration mode
Situation
Setup > License
Status bar
Licence file for another computer
The licence file is for another computer (red). It names both hardware IDs. "Not licensed: the program runs as a demonstration."
Demo - N min left (licence file for another computer); red banner at the bottom
Licence file ended
The licence has ended (red). "The licence ended on 01/11/2026. Ask your supplier for a new licence file." and "Not licensed: the program runs as a demonstration."
Demo - time is over (licence ended)
USB key without activation list
Key found, not activated
Demo - N min left (not activated)
Figure 19. Setup > License when the licence has endedFigure 20. Status bar after the licence ended
Note: Tested for this guide with a licence file that ended on 01/11/2026: on 27 October 2026 it showed Valid licence (file); after the Windows date was set to 2 November it showed The licence has ended within 30 seconds. Burning was then refused with the notices "demonstration time is over. Insert the licensed USB key (or restart the program) to burn discs." and "...or restart the program for another hour of demonstration." No burn job was created. This means a licence that ends also stops burning, so renew it in time.
A licence file only works on the computer whose hardware ID it was made for. Reseller and demonstration licences usually have an end date; when it passes, the status bar shows the reason (licence ended) and the program falls back to the demonstration mode.
Note: Tested for this guide: a one-year file (valid until 01/11/2027) and a lifetime file were each placed as DCMburner.lic in the licence folder, with no USB key in the computer. Both gave Valid licence (file) and License OK within 30 seconds. The USB key was activated with Download the activation list: the status changed from "Key found, not activated" to "Valid license" and USPK.lic (about 70 KB) was saved in the licence folder. The file dialog of Import the licence file... was not driven; the file was copied into the folder, which is what the import does.
7. Web pages on other computers
DCMburner makes its own HTTPS certificate. The first time, a browser on another computer warns that it does not know the certificate. Solve it once per computer:
Setup > Web access > Save the certificate for other computers.... This writes DCMburner-certificate.cer and Install-DCMburner-certificate.bat.
Give both files to the other computer (shared folder, USB stick or zip; e-mail often blocks .bat).
On that computer: right-click Install-DCMburner-certificate.bat and choose Run as administrator. It installs the certificate in "Trusted Root Certification Authorities".
Open https://<computer name or address>:8088 in the browser. Use the address from Setup > Web access (button Copy).
Figure 21. Setup > Web access
Firefox keeps its own list: Settings > Privacy & Security > Certificates > View Certificates > Authorities > Import.
Mac: Safari works after the certificate is set to "Always trust" in Keychain Access. If Chrome says ERR_ADDRESS_UNREACHABLE while Safari works, allow Chrome in System Settings > Privacy & Security > Local Network.
Your organisation can use its own certificate (.pfx, or certificate + key) or a certificate request (CSR). This was not tested against a real certificate authority.
8. Test the installation
Check that the status bar shows Receiving on <AE title> : 4006 and the publisher strip shows your robot.
Send a test study from a modality or use Q/R (see Getting Started).
Select the study and click Burn Disc. In demo mode the disc is written with the patient name DCMburner^Demo. With a valid licence the real patient names are written (tested: DICOMDIR and image files held MISTER^CT and so on).
Open Jobs: the job must change from In-Process to Completed.
9. Updating and uninstalling
Update: run the new installer. A running DCMburner is closed by the installer. Data and settings stay.
Uninstall
Close DCMburner with the Close button (the X of the window can only hide it in the system tray).
Open Windows Settings > Apps > DCMburner and choose Uninstall (or use the uninstall entry in the Start menu folder).
Answer Yes to "Are you sure you want to completely remove DCMburner and all of its components?".
The uninstaller asks "Remove the data of DCMburner as well?". Choose No to keep everything, for example when you install a newer version. Choose Yes only when you want a completely clean start.
Figure 22. The first question of the uninstallerFigure 23. The second question: remove the data as well?
What the data question removes. Yes removes the archive with the images, the database, the settings and the licence file in C:\ProgramData\sup-c\DCMburner. The reports and the log in the shared documents folder (C:\Users\Public\Documents\DCMburner) stay in both cases. A silent uninstall never removes the data.
Warning: After Yes the archive, the settings and the licence file are gone. At the next start DCMburner asks for a new administrator password, and a licence file must be placed again.
10. Installation problems
Problem
What to do
SmartScreen blocks the installer
More info > Run anyway.
WebView2 cannot be installed
Connect the computer to the internet once, or install the Microsoft Edge WebView2 Runtime first.
Studies do not arrive
Check the red message at the bottom (port in use), the AE title and port at the sender (default 4006), and the firewall.
Web pages not reachable from another computer
Switch on Allow other computers, allow the port in the firewall, install the certificate.
Robot status stays empty
Is the publisher software running? Is the job folder in Setup the same one it watches? Use Check this folder.